Filter
aillance international Multiplex Filter – 800 Lpm With Internal/External Backwash
Multiplex Filter – 800 Lpm With Internal/External Backwash
aillance international To Backwash
Backwash in necessitated due to clogged filter element. This is indicated by reduced pressure at outlet header. Follow the below mentioned procedure.

Close the Inlet and open Drain valve as shown in the sketch. Water enters from the Outlet header to inside of the filters and comes out through the openings of the filter wire. During this operation, all the dirt adhering to the filter will be flushed out and goes to drain

After one or two minutes of back washing, close the drain valve and open the inlet valve.
aillance international External Cleaning Of Filter
After Removal of Filter from unit, use a brass brush to clean the Outer Surface. Use mild caustic and clean it thoroughly using high pressure water. Replace unit carefully and tighten flanges, connect hose pipe.

aillance international Caution
Do not use Acid on Filter Element. This may cause damage to Filter element.

Multiplex Filter – 800 Lpm With Internal/External Backwash
 
   
aillance international Filter
aillance international What Is Filter
aillance international Filter Details
aillance international Principle of Operation
aillance international Filter Construction – Wire Mesh
aillance international Wire Wound
aillance international Application of Gve Filters In Pulp & Paper
aillance international Benefits & Features of Filter
aillance international Multiplex Filter – 800 Lpm With Internal/External Backwash
aillance international Flow of Water During Filtering And Back Washing of Duplex Filter
aillance international Multiplex Filters & Automatic Multiplex Filters
aillance international Principle of Operation of Automatic Filters
aillance international Automatic Multiple Filters Operation
aillance international Showers system
aillance international Nozzles
aillance international Questionnaire